Name:VZF-12R/T160-50 Central Sealed Vacuum Circuit Breaker

Overview:

• Classification Series :Indoor Vacuum Circuit Breaker

• Product Name :VZF-12R/T160-50 Central Sealed Vacuum Circuit Breaker

• Product Overview
VZF-12R built-in sealed vacuum load switch-fuse combination appliance (hereinafter referred to as vacuum switch) is the latest generation of vacuum switch equipment developed according to special design concepts and combined with market demand...


Service
VZF-12R/T160-50 Central Sealed Vacuum Circuit Breaker
Product Introduction

▸ Product Introduction

Description

The VZF-12R built-in sealed vacuum load switch-fuse combination appliance (hereinafter referred to as vacuum switch) is the latest generation of vacuum switch equipment developed according to special design concepts and combined with market demand. It is widely used in indoor armored air insulated switchgear, and it conforms to GB3804-2004 GB16926-1997 and other standards. 

The VZF-12R is equipped with a fixed-seal vacuum load switch-fuse combination. Under normal use conditions, it can ensure safe and reliable operation in power grids with corresponding voltage levels as long as it is within the technical parameters of the vacuum switch.


Environment Condition

1


Environment Condition

Ambient temperature: maximum temperature +40℃ , minimum temperature -25℃ .

Environmental humidity: Daily average relative humidity: ≤ 95%, monthly average relative humidity: ≤ 90%.

Daily average saturated vapor pressure: ≤ 2.2x10-3Mpa.

Monthly average saturated vapor pressure: ≤ 1.8x10-3Mpa.

Altitude: not higher than 1500m

Earthquake intensity: no more than 8 degrees.

Applicable places: No dripping water, no still and explosion hazard, no chemical corrosive gas, no severe vibration:

If the product usage environment exceeds the above regulations, users can negotiate with our company to determine.


Technical Data

Serial numberprojectUnitParameter
VZF-12/T630-20 vacuum load switchVacuum load switch - fuse combined electric appliance VZF-12/T125-50
01Rated voltageKV1212
02Power frequency withstand voltage (interphase and ground)KV4242
03Lightning strike (interphase, ground)KV7575
04Rated currentA630125(Fuse)
05Rated open circuit withstand currentkA-50(Fuse)
06Rated short-time withstand currentkA20-
07Rated peak withstand currentkA50-
08Rated breaking and closing currentkA50-
09Rated cable charging breaking currentA16-
10Rated breaking currentA-3150
11Breaking no-load transformerKVA1250

12Battery LifeTimes10000
13Partial discharge starPC≤5


Outline Dimension
2


Contact Information
  • Tel.:Manager Zheng:15319942044
  • Tel.:Manager Jin:18291881166
  • Email:service2@hwtmtrade.cn
    service1@hwtmtrade.cn
  • Location:Building 4, Enterprise No.1 Community, Yinshi Military Civilian Integration Industrial Park, No. 333 Yingbin Road, National Aviation High tech Industrial Base, Xi'an City, Shaanxi Province
Scan to follow the official official account Heweitongmao (Shaanxi) Import & Export Trade Co., Ltd.
15319942044 18291881166
Heweitongmao (Shaanxi) Import & Export Trade Co., Ltd.